Daily energy balance (GWh) (1) Day Month %∆ Month Annual %∆ Annual Rolling year (2) %∆ Rolling year
Hydro 119 1.088 8,1 1.088 8,1 33.781 -1,9
Nuclear 180 2.229 2,3 2.229 2,3 51.896 -0,9
Coal 0 0 -100,0 0 -100,0 1.413 -53,1
Diesel engines 7 86 -1,4 86 -1,4 2.545 0,4
Gas turbine 2 23 -9,0 23 -9,0 685 1,2
Steam turbine 12 126 357,1 126 357,1 2.460 111,3
Combined cycle (4) 154 1.749 55,0 1.749 55,0 46.354 31,9
Hydrowind 0 0 46,1 0 46,1 22 -5,0
Wind 265 3.426 -5,2 3.426 -5,2 58.568 -5,6
Solar PV 59 999 5,6 999 5,6 50.326 12,3
Solar thermal 0 18 -41,5 18 -41,5 3.669 -11,2
Other renewables (5) 11 136 2,5 136 2,5 3.912 5,3
Cogeneration (6) 49 583 -3,9 583 -3,9 15.489 -5,2
Non-renewables waste (7) 3 42 -8,3 42 -8,3 1.061 -20,9
Renewable waste (7) 2 32 5,5 32 5,5 713 -11,2
Generation 865 10.535 5,8 10.535 5,8 272.895 3,9
Pumped storage (8) 10 166 -14,1 166 -14,1 5.859 7,3
Batteries 0 0 56,4 0 56,4 8 -17,3
Pumped storage consumption -11 -271 -22,2 -271 -22,2 -9.077 4,0
Batteries consumption 0 0 58,7 0 58,7 -10 -15,8
Exchange balance (9) -22 -676 -3,4 -676 -3,4 -12.771 20,9
Demand (b.c) 842 9.755 7,1 9.755 7,1 256.904 3,3
Adjusted demand (10) - - 2,9 - 2,9 - 1,7
Transmission losses -17 -224 11,1 -224 11,1 -5.334 3,0
Demand (distribution) 825 9.530 7,0 9.530 7,0 251.570 3,3

Renewable energy

13/01/2026
January
2026
Rolling year aggregate
  • No renewable:
    • Diesel engines
    • Coal
    • Gas turbine
    • Nuclear
    • Steam turbine
    • Combined cycle
    • Hydrowind
    • Non-renewables waste
  • Renewable:
    • Cogeneration
    • Wind
    • Other renewables
    • Hydro
    • Solar thermal
    • Renewable waste
    • Solar PV

Renewable energy

Renewable energy (GWh) Day Month %∆ Month Annual %∆ Anual Rolling year (2) %∆ Rolling year
Total (11) 457 5.699 -1,1 5.699 -1,1 150.992 0,7
  • Note: All variance percentages shown refer to the same period in the previous year.
  • (1) Allocation of production units according to primary fuel.
  • (2) Rolling year: cumulative value in the last 365 days, or 366 days in leap years.
  • (3) Generation from auxiliary generators is included in the electricity systems of the Balearic Islands.
  • (4) Includes operation in open cycle mode. Power generation for the electricity system of the Canary Islands’ electricity system is obtained primarily from gas-oil.
  • (5) Includes biogas, biomass, marine energy and geothermal. The values of increase and rolling year include waste up until 31 December 2014.
  • (6) The increment and rolling year values include waste up to December 31, 2014.
  • (7) Generation included in other renewables and cogeneration up to December 31, 2014.
  • (8) Pure pumped storage + mixed pumped storage estimate.
  • (9) Positive value: import balance; negative value: export balance
  • (10) After factoring in the influence of seasonal and working patterns
  • (11) Includes hydro, wind, solar photovoltaic, solar thermal, other renewables and renewable waste.
     
  • * The information in this report does not include data on the estimated energy generated by self-consumption facilities.