Friday, 30 April 2021
Daily statistics of the national electricity system
Definitive data to 10/11/2022 • 18:50:35
Daily energy balance (GWh) (1) | Day | Month | %∆ Month | Annual | %∆ Annual | Rolling year (2) | %∆ Rolling year |
---|---|---|---|---|---|---|---|
Hydro | 106 | 2.745 | -4,1 | 15.035 | 19,9 | 33.123 | 15,8 |
Pumped storage (3) | 2 | 154 | -51,1 | 1.206 | 11,5 | 2.876 | 38,9 |
Nuclear | 130 | 4.197 | 2,7 | 18.589 | -4,4 | 54.912 | -1,2 |
Coal | 10 | 270 | -11,5 | 1.246 | -49,5 | 3.800 | -50,1 |
Fuel oil+gas | 10 | 283 | 0,7 | 1.217 | -13,6 | 4.002 | -22,9 |
Combined cycle (5) | 142 | 3.384 | 56,1 | 9.809 | -9,4 | 43.004 | -20,9 |
Hydrowind | 0 | 1 | -15,7 | 5 | 0,0 | 20 | -13,7 |
Wind | 75 | 4.096 | 10,9 | 23.099 | 27,0 | 59.811 | 12,6 |
Solar PV | 62 | 1.666 | 45,0 | 5.176 | 35,7 | 16.664 | 60,1 |
Solar thermal | 11 | 267 | 29,0 | 863 | 14,0 | 4.644 | 0,1 |
Other renewables (6) | 14 | 392 | 16,1 | 1.508 | 10,3 | 4.622 | 21,4 |
Cogeneration (7) | 78 | 2.193 | 13,7 | 8.691 | -1,7 | 26.879 | -5,0 |
Non-renewables waste (8) | 6 | 178 | 27,6 | 718 | 9,8 | 2.080 | 0,0 |
Renewable waste (8) | 3 | 74 | 112,2 | 276 | 22,9 | 777 | -4,6 |
Generation | 649 | 19.900 | 13,7 | 87.437 | 7,1 | 257.214 | 0,2 |
Pumped storage consumption | -2 | -217 | -68,1 | -2.081 | 0,4 | -4.637 | 16,5 |
Exchange balance (9) | 42 | 257 | 10,4 | 499 | -84,6 | 534 | -91,6 |
Demand (b.c) | 689 | 19.940 | 16,9 | 85.855 | 3,7 | 253.111 | -2,3 |
Adjusted demand (10) | - | - | 16,0 | - | 2,9 | - | -2,6 |
Transmission losses | -9 | -335 | 9,4 | -1.688 | 19,6 | -4.406 | 8,8 |
Demand (distribution) | 680 | 19.605 | 17,0 | 84.167 | 3,4 | 248.705 | -2,4 |
Generation structure
30/04/2021
April
2021
Rolling year aggregate
-
No renewable:
- Coal
- Nuclear
- Pumped storage
- Combined cycle
- Fuel oil+gas
- Non-renewables waste
- Cogeneration
-
Renewable:
- Other renewables
- Hydrowind
- Solar thermal
- Hydro
- Solar PV
- Renewable waste
- Wind
Renewable energy
Renewable energy (GWh) | Day | Month | %∆ Month | Annual | %∆ Annual | Rolling year (2) | %∆ Rolling year |
---|---|---|---|---|---|---|---|
Total (11) | 272 | 9.241 | 11,5 | 45.962 | 24,5 | 119.661 | 18,0 |
- Note: All variance percentages shown refer to the same period in the previous year.
- (1) Allocation of production units according to primary fuel.
- (2) Rolling year: cumulative value in the last 365 days, or 366 days in leap years.
- (3) Pure pumped storage + mixed pumped storage estimate.
- (4) Generation from auxiliary generators is included in the electricity systems of the Balearic Islands.
- (5) Includes operation in open cycle mode. Power generation for the electricity system of the Canary Islands’ electricity system is obtained primarily from gas-oil.
- (6) Includes biogas, biomass, marine energy and geothermal. The values of increase and rolling year include waste up until 31 December 2014.
- (7) Generation included in other renewables and cogeneration on 12/31/2014.
- (8) Generation included in other renewables and cogeneration up to December 31, 2014.
- (9) Positive value: import balance; negative value: export balance
- (10) After factoring in the influence of seasonal and working patterns
- (11) Includes hydro, wind, solar photovoltaic, solar thermal, other renewables and renewable waste.